12
Operating preset memory (PMEM)
The preset memory of a remote camera can be operated from the unit .
The following settings that you have adjusted in advance can be stored
in preset memory .
z
z
Pan/tilt positions
z
z
Zoom positions
z
z
Focus positions
z
z
Lens iris settings (manual iris only)
z
z
White balance settings
z
z
Gain
z
z
If the MEM ENABLE button indicator is off, preset memory
operation is not possible . Press the button to turn on its indicator
and then perform operation .
z
z
Preset numbers PMEM 1 to 10 are also used as start positions
when recalling tracing memory . Preset data may be overwritten
by tracing memory operation .
z
z
The number of preset memory that can be registered differs
depending on the remote camera .
For details, check the Operating Instructions for the
corresponding model .
z
z
The white balance setting and gain are registered to only the
preset memory of AW‑HE50, AW‑HE60, and AW‑HE120 .
The white balance setting that is registered is that which results
from application of manual R/B gain adjustment to the automatic
white balance adjustment .
When the preset memory is recalled, the same color tones as at
the time of registration are reproduced but the R/B gain values
become 0 .
Notes
PMEM button
Number buttons
[1] to [50]
PMEM PAGE
button
PMEM PAGE
indicators
MEM SETTING button
MEM DELETE button
MEM STORE button
MEM ENABLE button
z
z
Changing pages
Press one of the number buttons [1] to [50] to directly select any of the
50 preset memory .
Furthermore, pressing the PMEM PAGE button to change pages allows
you to operate up to 100 preset memory for each camera .
Press the PMEM
PAGE button .
Page 1 selected
Page 2 selected
Button indicator on
Button indicator on
<Preset numbers and registered pages>
Preset number
Page number Number button
PMEM 1 to PMEM 50
Page 1
[1] to [50]
PMEM 51 to PMEM 100
Page 2
Example: When specifying preset number “PMEM 51”
1 . Press the PMEM PAGE button to select Page 2 .
2 . Press number button [1] .
z
z
Lighting of number button indicators
The lighting method of the number buttons differs depending on the
remote camera or pan‑tilt head that the unit is controlling .
<Lighting method of number button indicators>
Remote cameras and
pan‑tilt heads
Lighting method of number button
indicators
AW‑HE50, AW‑HE60,
AW‑HE120
The indicators of the number buttons with
preset memory registered turn on .
AW‑HE100, AW‑PH360,
AW‑PH405, AW‑PH650,
AW‑PH400
The indicator of the number button that
was last pressed turns on .
However, when preset memory is deleted
in DELETE mode, all of the number
buttons turn off .