![Panasonic AK-UCU600E Operating Instructions Manual Download Page 26](http://html.mh-extra.com/html/panasonic/ak-ucu600e/ak-ucu600e_operating-instructions-manual_262647026.webp)
Parts and their functions
- 26 -
Rear panel 2
8
10
1
2
3
4
5
6
9
11
7
1 [LAN] connector
It is the LAN connector (RJ45) for connecting the ROP (AK-HRP1000 / AK-HRP1005) with an IP
connection.
Use a switch hub and connect the devices with a 10BASE-T/100BASE-TX straight cable. This
connector is for connecting a personal computer when configuring Web settings.
“Web Screen” (see page 90)
2 [AUX] connector
This connector is used for controlling a waveform monitor and external systems (down-convert
system, MIC gain selection, alarm output, or tally output).
3 [TRUNK] connector
This connector provides two systems for 2-way communication of camera trunk data (RS-422
and RS-232C).
4 [COMMUNICATION] connector
This connector is for connecting the intercom signals and tally signals to the external system.
5 [ROP] connector
This connector is for connecting a ROP (sold separately).
6 [MSU] connector
This connector is for connecting an MSU (sold separately).
7 [MIC1] and [MIC2] connectors
These connectors are for outputting the analog signals of microphones 1 and 2 of the camera.
The microphone level is 0 dBm/600 Ω.
8 [CAMERA] connector
This connector is for connecting the optical fiber multi cable (sold separately).
9 Cooling fan
This is the unit's cooling fan.
10 AC power socket
This socket is for inputting AC power.
Connect the supplied power cable, and use a 3-prong outlet and ground the unit properly.
11 [SIGNAL GND] terminal
Connect this to the system ground.