Parts and their functions
- 25 -
9 [REF] connectors
These connectors (BNC) are for inputting reference signals.
Black burst (BB) signals and tri-level sync signals can be input, and the type of signals input is
recognized automatically.*
1
When no cable is connected to the loop-through output connector (B), the connector is
automatically terminated at 75 Ω.
Connecting a cable to this connector releases 75 Ω termination.
When a cable is connected to the loop-through output connector (B), be sure to connect the
other end of the cable to a connector.
A
B
A.
Reference signal input connector
B.
Loop-through output
*1: When the [CCU MODE] is [1080/23.98psF], input 1080/23.98psF (47.95 Hz) tri-level sync
signals.
For details on supported sync signals for each format, see "Front panel [G/L ON] indicator
specifications."
“Front panel [G/L ON] indicator specifications” (see page 130)
10 [LAN TRUNK] connector
LAN communication is carried using optical transmission between the camera and CCU.