- 237 -
If a problem is detected immediately after the unit is turned on or while you are operating it, the status indicator and an
on-screen display report the problem.
Warning Indications
System error
Status indicator
It flashes once per second.
On-screen display
s
Meaning of the warning
A reference signal error or communication
error has occurred.
Recording/playback
The operation stops.
Solution
Turn off and on this unit. If the warning
persists, consult your dealer.
The battery is depleted
(Low input voltage)
Status indicator
It flashes once per second.
On-screen display
The message [LOW BATTERY.] is
displayed.
Meaning of the warning
The battery is depleted.
Recording/playback
The operation stops. This unit turns off
automatically.
Solution
Charge or replace the battery.
Connect the AC adaptor to cancel the
warning.
Low input voltage to the
DC input terminal
Status indicator
It flashes once per second.
On-screen display
The message [Low DC power] is
displayed.
Meaning of the warning
The voltage entering the DC input terminal
is low.
Recording/playback
The operation stops. This unit turns off
automatically.
Solution
Attach a charged battery.
The card is full
Status indicator
s
On-screen display
The remaining recordable time flashes red
when it reaches [R 0h00m].
Meaning of the warning
The SD card capacity is full.
Recording/playback
The recording stops.
Solution
Delete unnecessary clips, or use a new
SD card.
AG-UMR20PJ.EJ(DVQP1321ZA)_E.book 237 ページ 2017年5月22日 月曜日 午後2時11分