INF-47
Overall Check
Execute the “DATA INIT.”. Refer to item “4-5. DATA INIT.”(page INF-15).
Turn the power OFF and ON.
Turn the power OFF and ON.
Load the backed up Scene file data to new board.
Load the backed up Setting menu data (USER FILE) to new board.
Write the 1394 UID(P2 and SBP2) numbers.
If the numbers are missed, so please contact the Panasonic Service Engineering.
Regarding UMID writing procedure, refer to item
“8. UID Writing Procedure”
(page
INF-39
).
Write the Serial Number.
With Serial Number Writing Procedure, please contact Panasonic Service Engineering.
Rewriting setting of data according to destination.
Refer to item
“9. Rewriting setting of data according to destination”
(page
INF-40
).
In case of the CAC files saved on the camera recorder is the same as the time of factory
shipments, initialization of CAC data is executed. (LENS SETUP menu
→
CAC FILE INIT)
* The CAC data file at the time of factory shipments can be confirmed on the support page
of the following website. Moreover, the CAC data file and the added CAC data file at the
time of factory shipments are downloadable on the support page of the following website.
Please return a CAC file to the state before board exchange.
http://eww.pavc.panasonic.co.jp/pro-av/