Table 4: Modbus address list – holding registers for flare meter validation (analog inputs)
Register tag name
Register
address
Number of
registers
Description
SOUNDSPEED_CH2
2204
2
Ch 2 sound speed from flare meter
SIG_STRENGTH_CH2_UP
2206
2
Ch 2 upstream signal strength from flare meter
SIG_STRENGTH_CH2_DN
2208
2
Ch 2 downstream signal strength from flare meter
SIG_QUALITY_CH2_UP
2210
2
Ch 2 upstream signal quality from flare meter
SIG_QUALITY_CH2_DN
2212
2
Ch 2 downstream signal quality from flare meter
AMPLITUDE_CH2_UP
2214
2
Ch 2 upstream amplitude from flare meter
AMPLITUDE_CH2_DN
2216
2
Ch 2 downstream amplitude from flare meter
PEAKNUM_CH2_UP
2218
2
Ch 2 upstream peak number from flare meter
PEAKNUM_CH2_DN
2220
2
Ch 2 downstream peak number from flare meter
TTIME_CH2_SKAN_UP
2222
2
Ch 2 upstream transit time, skan from flare meter
TTIME_CH2_SKAN_DN
2224
2
Ch 2 downstream transit time, skan from flare meter
TTIME_CH2_MEAS_UP
2226
2
Ch 2 upstream transit time, measure from flare meter
TTIME_CH2_MEAS_DN
2228
2
Ch 2 downstream transit time, measure from flare meter
DELTA_T_CH2_SKAN
2230
2
Ch 2 upstream Delta T, skan from flare meter
DELTA_T_CH2_MEAS
2232
2
Ch 2 upstream Delta T, measure from flare meter
PATH_LENGTH_CH2
2234
2
Ch 2 path length from flare meter
AXIAL_LENGTH_CH2
2236
2
Ch 2 axial length from flare meter
32
Summary of Contents for flare.IQ Generation 2
Page 1: ...flare IQ Generation 2 Operation and maintenance manual...
Page 2: ...2...
Page 3: ...flare IQ Generation 2 Operation and maintenance manual 910 350 rev A June 2020 3...
Page 4: ...no content intended for this page 4...
Page 38: ...Figure 30 System wiring diagram 38...
Page 48: ...48...