Chapter 1. Programming Site Data
34
DigitalFlow™ GS868 Programming Manual (2-Channel)
IMPORTANT:
Once the system has been locked, it can only be unlocked by entering the password, because access to
the
SECUR
submenu is restricted.
To program the
SECUR
submenu, press
] and
[F1]
at the
Global PROGRAM
prompt. Refer to Figure 13 on page 85.
IMPORTANT:
It is recommended that all program parameters be recorded before changing the password. (This
information should be recorded in Appendix B, Data Records, as a matter of routine.) If the password is
lost, the site data is not retrievable and will have to be re-entered.
1.
At the
Lock Out prompt, press
[F1]
= UNlck
to unlock the system and return to the
Global PROGRAM
prompt, or
press
[F2]
= LOCK
to lock the system.
Note:
If the system was unlocked at the above prompt, the following three prompts do not appear.
2.
Enter the current Password (
2719
is the default password) and press
[ENT]
.
3.
At the
?Edit Password prompt, press
[F1] = NO
to leave the password unchanged and return to the
Global
PROGRAM
prompt, or press
[F2]
= YES
to enter a new password.
IMPORTANT:
Since the default password is printed in this manual, a new password should be entered. If the password
is ever lost, contact the factory for assistance.
4.
Enter the New Password and press
[ENT]
. Any combination of letters and numbers up to a total of 21 characters
may be used as a password.
Note:
Keep in mind that the password may have to be entered frequently from the keypad. A long and/or complex
password may soon become annoying to use.
5.
Verify the New Password by entering it again and press
[ENT]
. Be sure to record the new password in a safe
place.
Procedure Options
After completing the above steps, the meter returns to the
Global PROGRAM
prompt. Continue as follows:
• To continue programming the meter, refer to the menu maps in Appendix A and navigate to the desired menu.
Then, proceed to the appropriate section of this manual for instructions.
• To leave the
User Program and retain the previous settings, press
[EXIT]
twice and then press
[F1] = NO
at the
SAVE prompt. Any programming changes will be discarded and you will be returned to the data display.
• To leave the
User Program and return to measurement mode, press
[EXIT]
twice and then press
[F2] = YES
at
the
SAVE prompt. Your programming changes will be entered into the meter’s memory, and you will be
returned to the data display.
Note:
See the
SAVE
submenu section on the following page for more information on this function
Summary of Contents for DigitalFlow GS868
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 10: ...Contents viii DigitalFlow GS868 Programming Manual 2 Channel...
Page 91: ...DigitalFlow GS868 Programming Manual 2 Channel 81 Appendix A Menu Maps...
Page 92: ...82 DigitalFlow GS868 Programming Manual 2 Channel...
Page 100: ...DigitalFlow GS868 Programming Manual 2 Channel 90...
Page 104: ...94 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Page 122: ...112 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Page 136: ...126 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Page 140: ...Index 4 DigitalFlow GS868 Programming Manual 2 Channel...
Page 144: ...Chapter 2 DigitalFlow GS868 Programming Manual 2 Channel...
Page 145: ......