Chapter 2.
20
Model CTF878 Startup Guide
Figure 7: Locating Damping Material with a CFT-PI Clamping Fixture Installed
2.1.9
Applying DMP-3 Damping Material
For some applications, particularly on higher-temperature pipes, DMP-3 compound should be used.
Note:
If the pipe temperature is over 150°F, a PDJ pipe damping jacket with DMP-3 damping material applied is
required (see Installing the PDJ Damping Jacket on page 23).
Preparing the Pipe
To prepare the pipe for DMP-3 application:
1.
Remove any loose paint or rust from the pipe surface with a file or emery cloth. If the finish is mirror-smooth,
roughen the surface.
TOP VIEW
SIDE VIEW
CFT-PI CLAMPING FIXTURE
DAMPING MATERIAL
Summary of Contents for CTF878