![Panametrics CTF878 Startup Manual Download Page 9](http://html1.mh-extra.com/html/panametrics/ctf878/ctf878_startup-manual_3401710009.webp)
Model CTF878 Startup Guide
1
Chapter 1.
Chapter 1.
1.1
Features and Capabilities
1.1.1
Overview
The Model CTF878 Clamp-On Tag Flowmeter represents one of the most technologically advanced flow
measurement systems in the world. It measures the flow rate of acoustically conductive single-phase gases. Unlike
most ultrasonic gas flowmeters, however, the CTF878 does not require the tapping of a pipe. It works with external
clamp-on ultrasonic transducers that do not interfere with gas flow.
Just clamp the transducers to the pipeline, follow some simple acoustic damping guidelines, program a few meter
settings, and start collecting flow data for months (or even years) with no maintenance.
The CTF878 represents a new level of capacity compared to previous gas clamp-on systems, in that it can measure
flow rates up to and greater than 150 ft/sec (46 m/sec), and it is less susceptable than previous systems to
cross-flow disturbances.
1.1.1.1
Electronics Package
In addition to the built-in LCD display, the flowmeter provides the following:
1.
Two 0/4–20mA isolated outputs with a 550
maximum load.
2.
Six additional slots available for any combination of the following I/O boards:
a.
Analog outputs: Select up to three additional output boards, each with four isolated 0/4–20 mA outputs, 1 k
max.
load
b.
Analog inputs: Select up to three boards of one of the following types:
•
Analog Input Board with two isolated 4–20 mA inputs and 24 V loop power
•
RTD Input Board with two isolated three-wire RTD inputs; span –148° to 662°F (–100° to 350°C); 100
Pt
c.
Totalizer/Frequency outputs: Select up to three Totalizer/Frequency Output Boards each with four outputs per
board,
10 kHz max. All boards allow software-selectable functioning in two modes:
•
Totalizer Mode: Pulse per defined unit of parameter
(e.g., 1 pulse/ft
3
)
•
Frequency Mode: Pulse frequency proportional to magnitude of parameter (e.g., 10 Hz = 1ft
3
/hr)
Summary of Contents for CTF878
Page 1: ...panametrics com Flow 910 254U Rev A AUG 2021 Model CTF878 Clamp On Tag Flowmeter Startup Guide...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 6: ...Warranty iv Model CTF878 Startup Guide no content intended for this page...
Page 8: ...Contents vi Model CTF878 Startup Guide...
Page 76: ...Model CTF878 Startup Guide 68...
Page 96: ...Appendix A 88 Model CTF878 Startup Guide...
Page 99: ...Model CTF878 Startup Guide 91 Appendix B 9 21 10 22 11 23 12 24...
Page 100: ...Appendix B 92 Model CTF878 Startup Guide...
Page 104: ...Index 96 Doc Tittle Manual Type...
Page 106: ......
Page 107: ......