MAINTENANCE
M-1728 2-6-20-5
PLANETARY GEARBOX
Change gear box oil using API-GL-5, 80W or 90W lubricant after the first 50 hours of
operation and then every 1000 hours or 12 months, whichever comes first. Check oil level fre
-
quently to maintain proper lubrication. Oil should be at operating temperature when checking
or changing gear box oil.
NOTE: Place planetary in a horizontal position and wait 5 minutes before removing drain
plug. This will give the oil a chance to drain from gears/bearings and therefore show an
accurate oil level.
CHECKING PLANETARY LUBRICANT (DIGGA PLANETARIES)
1.
Place the planetary in a horizontal position.
PLANETARY
DRAIN PLUG
PLANETARY
DRAIN PLUG
CHECKING PLANETARY LUBRICANT (AUBURN PLANETARIES)
1.
Place the planetary in a horizontal position.
2.
Remove drain plug.
3.
Check the lubricant level. Gear lub level
should be visible through the drain plug
port and up to the bottom of the threads.
4.
To Fill: Place the planetary in a
horizontal position and add lubricant up
to the threads of drain plug port. Do not
overfill. Oil capacity is approximately .75
(3/4) quarts.
2.
Remove drain plug.
3.
Check the lubricant level. Gear lub
level should be visible through the
drain plug port and up to the bottom
of the threads.
4.
To Fill: To Fill: Place the planetary in
a horizontal position and add lubri-
cant up to the threads of drain plug
hole. Do not overfill. Oil capacity is
approximately .62 (5/8) quarts.
75623
19