User’s Manual
12
14.
Move to
Sequence dwell
, and set the sequence dwell time for the main monitor by holding down and dragging
the pointer. If you set the value to
3
seconds for the Sequence dwell, the camera display will sequence every three
seconds on the Main monitor.
15.
Move to
Screen saver dwell
, and set the screen saver dwell time for the display image. The screen saver will be
activated if there is no keyboard or mouse operation during the preset dwell time.
16.
Move to
Auto Deletion
, and check the box
if you want to delete the video recorded earlier than user-defined
period. When checking the
Auto deletion
box, move to
Period
and set the period to keep the recorded video. e.g.
If you check the
Auto deletion
box, and set 30 days in the
Period
box, the DVR will automatically delete the
video which is older than 30 days from the current day.
17.
Move to
Show OSD
, and check the box if you want to display OSD information on the image. OSD information
includes camera title, recording mode and recording status and event detection status.
NOTE:
A
R
indicates the target camera is in the
Time-lapse
recording schedule mode. An
E
indicates it is in the
Event-driven
recording mode. A
R/E
indicates it is in the
Time & Event
recording mode. A
R
located at the
bottom-right corner indicates the DVR is recording video, and the blink rate of the
R
relates to the recording
speed. A
■
icon displaying at the bottom-left corner indicates that motion detection or object detection events
occur.
18.
Move to
Remote control
, and click the
Set up Remote control...
button when the DVR is controlled remotely
using the serial communication signals or via network connections.
19.
Move to
Control Protocol
, and select the protocol from the drop-down list that the connected remote control
device supports.
20.
Move to
Serial (RS232 / RS485)
, and check the box and click the
Set up Serial
when the DVR is controlled
remotely using the serial communication signals. Select the DVR's COM port to use from the drop-down list.
Click the
Set up port...
button, and set the
Baud rate
from 300 to 256,000. Select
Parity
from
None
,
Even
or
Odd
parity. Select
Data bit
from
7 bit
or
8 bit
format. Select
Stop bit
from
1 bit
or
2 bits
from the drop-down
list. Move to
Device ID
, and set the device ID number from 0 to 127 using the slide bar. See
Appendix 9 –
Protocol for Remote Controlling DVR
for details.
NOTE:
When using the RS485 port on the extension card, select the given
COM Port
number. To check the
given COM port number, please refer to the installed card information displayed on the
System Info.
dialog box
by clicking the
System Info.
button.
21.
Move to
Network
, and check the box and click the
Set up Network
when the DVR is controlled remotely via
network connections. Enter the
Network Port
number.