1
3. PREPARATION
Priming Operation
1 Fully submerge filter and
return pipe in coating
material.
3 To set the pressure control
dial correctly, align the
central mark with the
desired setting icon.
4 Set priming lever to prime,
then turn unit on.
2 Set pressure control dial to
prime.
2. ASSEMBLY CONT.
Locking the Spray Gun Trigger
1 To lock the spray gun
trigger, rotate the trigger
locking screw anti-
clockwise.
The spray gun trigger should be locked prior to preparing the spray
station to ensure the trigger does not accidentally get released.
2 To unlock the trigger, rotate
the trigger locking screw
clockwise.
Note:
Do not thin paint for use in this spray gun.
Spray Tip & Guard
1 Insert the mesh
filter into the
handle and align
the handle with the
upper part of the
spray gun.
2 While holding the
upper section of
the spray gun,
tighten the handle
using a 21mm
spanner.
Note:
The spray gun comes assembled from the factory. If the
spray gun has been disassembled for cleaning, follow the steps
below to re-assemble.
3 Slide the trigger guard onto
the tab on the handle and
tighten using a 3mm hex
key and spanner.
5 Place guard over end of
gun then insert nozzle tip.
4 Ensure the small spacer
and washer that locate the
nozzle tip are inserted in
the nozzle.
6 Tighten retaining nut.
WARNING!
THIS TOOL IS RECOMMENdEd FOR THE
USE WITH RESIdUAL CURRENT dEvICE WITH A
RATEd RESIdUAL CURRENT OF 30MA OR LESS.