159
OXE 150/200 HP SERVICE MANUAL
INTAKE MANIFOLD REPLACEMENT
-
Use a noise reducing air gun and wear hearing protection when
peak noise levels are greater than 85 decibels. Excessive noise may
cause hearing loss and rupture eardrums.
-
Wear
the appropriate gloves to protect your hands.
-
Never
use compressed air to clean your clothes or body.
-
Never
tamper with air guns to modify them in any way.
-
Never
point an air gun or direct air towards another individual or
your skin. Compressed air entering the bloodstream through a
break in the skin or through a body opening can create an air bubble
(embolism), a dangerous (and potentially deadly) medical condition.
-
Dangling hoses can present a trip hazard.
4.
Clean the passages
(1)
with compressed air
(2)
if necessary. Use a
maximum of
172 kPa (25 psi)
of air pressure.
5.
Replace the intake manifold as necessary.
INTAKE MANIFOLD ASSEMBLY
1.
Install the absolute pressure sensor
(3)
to the intake manifold
(2)
.
2.
Install the absolute pressure sensor bolt
(4)
.
3.
Install a
new
seal ring
(1)
.