234
OXE 150/200 HP SERVICE MANUAL
7.
Mount the starter motor cable
(2)
horizontally.
8.
Mount the starter motor supply cable
(3)
to the starter motor solenoid (
1
) and lead it as vertical as
possible.
!
CAUTION
Ensure no fretting on starter motor cables
(4)
. Recommended clearance >10 mm (>0.394 in).
9.
Connect the crankcase sensor connector
(5)
.
NOTE!
Ensure it
click's
.
10.
Slide the secondary lock (yellow) in place.
ELECTRICAL SYSTEM