4.Advanced User Guidebook
92
The horizontal cursors are set as the
intersections of the vertical cursors and the
waveform
Line
Type
(Time&Volt
age type)
Time
Voltage
Makes the vertical cursors active.
Makes the horizontal cursors active.
Window
(Wave
zoom
mode)
Main
Extension
Measure in the main window.
Measure in the extension window.
Line
a
b
ab
Turn the
M
knob to move line a.
Turn the
M
knob to move line b.
Two cursors are linked. Turn the
M
knob to
move the pair of cursors.
Source
CH1 to CH4
Display the channel to which the cursor
measurement will be applied.
Perform the following operation steps for the time and voltage cursor
measurement of the channel CH1:
1. Push
Cursor
to display the cursor menu.
2. Select
Source
in the bottom menu, select
CH1
in the right menu.
3. Select the first menu item in the bottom menu, the
Type
menu will
display at the right of the screen. In the right menu, select
Time&Voltage
for Type, two blue dotted lines displayed along the
horizontal direction of the screen, two blue dotted lines displayed along
the vertical direction of the screen. Cursor measure window at the left
bottom of the screen shows the cursor readout.
4. In the bottom menu, select
Line Type
as
Time
to make the vertical
cursors active. If the
Line
in the bottom menu is select as
a
, turn the
M
knob to move line a to the right or left. If
b
is selected, turn the
M
knob
to move line b.
5. In the bottom menu, select
Line Type
as
Voltage
to make the
horizontal cursors active. Select
Line
in the bottom menu as
a
or
b
,
turn the
M
knob to move it.
6. Push the
Horizontal
HOR
button to enter wave zoom mode. In the
bottom cursor menu, select
Window
as
Main
or
Extension
to make
the cursors shown in the main window or zoom window.