Owandy Visteo – User manual 

Page 15/30 

 

3.5  Sharing the sensor and box between different workstations 

Sharing the sensor and the box allows you to use one or more sensors in turn in a practice with multiple 
chairs. It is recommended to link the different workstations in a network to allow for the central storage and 
sharing of the images. 
 
The Visteo kit can be shared between different workstations in different ways: 
 

 

By  moving  the  sensor  and  connection  box  from  workstation  to  workstation;  in  this  case  a  USB 
cable must be plugged into each workstation to allow for an easy connection of the box.  

 

By  moving  only  the  sensor  from  workstation  to  workstation;  a  connection  box  and  a  USB  cable 
must be plugged into each workstation to allow for an easy connection of the sensor. 

 
Windows  will  automatically  recognise  the  equipment  when  it  is  connected  and  it  will  be  available 
immediately for image acquisition. 
 
To  enable  the  sharing  of  a  kit  between  different  workstations,  it  is  necessary  to  first  install  the  imaging 
software for the acquisition of the images, the drivers, O.S.P. tools and sensor installation files on all the 
computers to which the box will have to be connected. 
 
 

Summary of Contents for Visteo

Page 1: ...Visteo INSTALLATION AND USER MANUAL Version 42 02 December 11 2009...

Page 2: ...ION OF AN IMAGE 22 4 6 EXPOSURE TIME 24 5 HYGIENE AND MAINTENANCE 25 5 1 HYGIENE AND DISINFECTION 25 5 2 RECOMMENDED CLEANING AND DECONTAMINATION PROCEDURE 26 5 3 MAINTENANCE 26 6 TROUBLESHOOTING 27 6...

Page 3: ...uality such as the type and age of the chemical product the temperature of the baths or the development time The sensor is available in two sizes depending on the kit you have ordered you received a s...

Page 4: ...tions and guidelines of the installation chapter to install the equipment and software User the kit must be used by a dental practitioner The connection box should never be opened by the user Only the...

Page 5: ...the sensor and box kit in its original packaging after having cleaned it thoroughly Documentation loss all kits are shipped with its documentation Please contact your distributor for a replacement man...

Page 6: ...ompatible with Visteo size 1 and 2 sensors cable of 1m 3 3feet Bite blocks bitewing and endo for positioner Aiming ring for positioner 1 sensor and box wall support with 2 screws 2 plugs 1 strap Box p...

Page 7: ...proper functioning of the sensor kit Verify the specifications of the computer s before the installation Operating system Vista Windows XP service pack 1 Computer Motherboard USB port Compliant CE IE...

Page 8: ...doubt have your generator checked by a qualified technician Make sure he had of the generator is stable any movement of the head will induce movement blur in the acquired image 3 2 Equipment installat...

Page 9: ...an acquisition or during an acquisition you could damage it The USB cable can be connected disconnected without the need to power down the computer Check that the box is correctly connected switch it...

Page 10: ...h the support with the strap you can use the strap to attach the support e g to the chair the arm of your X ray generator to the head rest of your chair Pass the strap through the slits in the support...

Page 11: ...the O S P CD ROM The driver files are then copied to your hard disk 6 Click on Continue in the message window Equipment installation that appears 7 A confirmation window is displayed after the files h...

Page 12: ...he installation of the drivers 1 Select the desired language in the window that appears and click on Next 2 In the welcome screen click on Next 3 Select the target directory the directory where the so...

Page 13: ...S P CD ROM 2 Navigate to the setups CMOS_XRAYS_BOX_W2000_WXP directory on the CD ROM 3 Launch setup exe 4 Click on Install or Reinstall and follow the instructions on screen 3 4 Configuration in the...

Page 14: ...t the option Auto contrast the contrast is constant Exposure errors are corrected automatically which reveals noise in badly exposed images In both cases the exposure bar blue green red helps to find...

Page 15: ...tion in this case a USB cable must be plugged into each workstation to allow for an easy connection of the box By moving only the sensor from workstation to workstation a connection box and a USB cabl...

Page 16: ...All lights are off when the box is in standby mode and the sensor toolbar turns red To reactivate the box you only need to push the button on the box The lights inform the user about the state of the...

Page 17: ...to unclip it from the positioner or sensor connection cable 4 3 2 Positioner The universal positioner allows for the positioning of the sensor in the mouth with the technique of parallel positioning T...

Page 18: ...er push the bite block against the ridge The bite block can also be used for other type of images The bite block must in this case be moved away from the ridge to be able to rotate it on the rod of th...

Page 19: ...in this case maintained by the patient as with conventional film This can be necessary for children with a small mouth Clip the sensor to the sensor connection cable and position the sensor in the mou...

Page 20: ...ears in the Windows taskbar next to the clock The colour of the icon indicates the state of the sensor Red sensor inactive Yellow sensor initialising Green sensor ready for acquisition 4 4 2 Sensor to...

Page 21: ...acquired this option is not displayed Exit Closes the resident software program Warning the acquisition will no longer be available until the resident program is restarted 4 4 4 Image transfer interfa...

Page 22: ...d 13 Turn the sensor to position it vertically or parallel to the axis of the tooth if necessary use a roll of cotton to position the sensor correctly Position the sensor towards the centre of the mou...

Page 23: ...ight of the box will blink to indicate the treatment and transmission of the acquired image Once the image treated it appears in the imaging software and the blue light of the box lights up allowing a...

Page 24: ...t patient young man or woman of average size Distance focal spot to sensor 250mm 9 8inch Total inherent filtration equivalent to 2mm 0 08inch Al The values indicated in the table above can vary from o...

Page 25: ...of your practice The sensor and the head of the positioner or of the sensor connection cable must be covered by the hygienic protective sheath Validated protections for North America BANTA HEALTHCARE...

Page 26: ...able are not being used and to protect them from any damage it is recommended to store them in their protective case or to hang them in the wall support Even when using protective sheaths the sensor s...

Page 27: ...nnected correctly to the box and to the computer and that the computer is switched on If you use a USB hub check its connections and make sure it is powered on Check that the sensor is connected corre...

Page 28: ...r is positioned too far from the patient with regard to the selected dose Check the parameters of your monitor contrast and brightness and avoid reflections on the screen The images are too dark e g T...

Page 29: ...900mm 2 1 3 x 1 0pouce 1 3inch 2 1700 x 1300pixels 20 x 20 m Technical specifications size 1 and 2 sensors Maximum external dimensions of connection box 13 8 x 4 6 x 1 7cm 5 4 x 1 8 x 0 7inch Length o...

Page 30: ...2 sensors Contact your distributor Optional Visteo size 1 or 2 sensor kit with its accessories Contact your distributor 8 2 Accessories Positioning accessories DA001 Universal positioner DA002 Sensor...

Reviews: