Error
Code
Description
User Action
Critical Component Status
90
Cannot find elevator block
within the expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
•
Check elevator gears.
91
Cannot find rotation block
within the expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Cabling incorrect.
•
Check rotation gears.
92
Cannot find sled block
within the expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Cabling incorrect.
•
Check sled gears.
93
Gripper outside range,
Gripper has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
•
Check gripper gears.
94
Slider outside range,
Slider has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
•
Check slider gears.
95
Elevator outside range,
Elevator has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
•
Check elevator gears.
96
Rotation outside range,
Rotation has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Cabling incorrect.
•
Check rotation gears.
97
Sled outside range,
Sled has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Cabling incorrect.
•
Check sled gears.
98
Cartridge present sensor
not found
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Robotics controller defect.
•
Cartridge present sensor defect
(mechanics, electronics).
•
Cabling incorrect.
99
Sled home sensor not
found
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Robotics controller defect.
•
Slider home sensor defect
(mechanics, electronics).
•
Cabling incorrect.