Error
Code
Description
User Action
Critical Component Status
8A
Slider blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Slider Motor not connected or
defect.
•
Slider motor voltage to low.
•
Robotics controller or
distribution boards defect.
•
Check slider mechanism
according stiffness in movement.
8B
Elevator blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator motor not connected or
defect.
•
Elevator motor voltage to low.
•
Robotics controller or
distribution boards defect.
•
Check elevator mechanism
according stiffness in movement
8C
Rotation blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Rotation motor not connected or
defect.
•
Rotation motor voltage to low.
•
Rotation home sensor defect.
•
Rotation sensor connecting cable
damaged.
•
Robotics controller or
distribution boards defect.
8D
Sled blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Sled motor not connected or
defect.
•
Sled motor voltage to low.
•
Sled home sensor defect.
•
Sled sensor connecting cable
damaged.
•
Robotics controller or
distribution boards defect.
•
Check sled mechanism (guide
rail, ducktail) according stiffness
in movement.
8E
Cannot find gripper block
within the expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
•
Check gripper gears.
8F
Cannot find slider block
within the expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
•
Check slider gears.