NEO S-Series User Guide
10400666-001
© 2014 Overland Storage, Inc.
Page 16
NOTE
After upgrading the library firmware, the library system restarts
automatically.
To upgrade the library firmware, navigate with RMU or OCP:
RMU screen: > Service > Firmware > Upgrade Library Firmware > Upgrade
OCP screen: > Main Menu > Service > Service Library > Library FW Upgrade by USB
The actual library FW must be loaded on an USB stick to be connected on the backside of the unit. When Browse button
is pressed, the FW file name will be displayed and can be selected for upgrading.
General diagnostic
3.6
1.6.1 System test
The System Test: is a general test to verify the usability and reliability of the library. The duration is depending on the
test cycles defined.
To run the system test, navigate with RMU or OCP:
RMU screen: > Service > General Diagnostic > System Test
OCP screen: > Main Menu > Service > Service Library > Run Tests > System Test
Slot-to-Slot test
3.6.1
The Slot-to-Slot test shuffles the tapes between the slots to exercise the robotic. At the end of the test the tapes are not
returned to their original slots.
To run the Slot-to-Slot test, navigate with RMU or OCP:
RMU screen: > Service > General Diagnostic > Slot to Slot
OCP screen: > Main Menu > Service > Service Library > Run Tests > Slot to Slot Test
Library verify test
3.6.2
NOTE
The library will remove any tape from the tape drives and go offline
when running the test. Verify that any applications using the library
have completed before starting the test.
The Library verify test is a diagnostic routine called Library Health Check (LHC).
This routine allows:
•
to functionally test all library and drive hardware with the exception of external interfaces (SCSI).
•
to verify a newly installed machine.
•
to verify repair actions.
To run Library verify test, navigate with OCP:
OCP screen: > Main Menu > Service > Service Library > Library Verify
Operations during the Library Health Check (LHC):