NEO S-Series User Guide
10400666-001
© 2014 Overland Storage, Inc.
Page 19
Main error codes
3.7.4
Error
Code
Description
User Action
Critical Component Status
80
Barcode Reader Error,
cannot initialize BCR
Retry operation; after
several occurrences contact
technical support
Robotic probably defect
•
Flexi cable to BCR not properly
connected.
•
Flexi cable to BCR damaged.
•
Barcode engine defect.
81
Barcode Reader Error, no
response from BCR
Retry operation; after
several occurrences contact
technical support
Robotic probably defect
•
Flexi cable to BCR not properly
connected.
•
Flexi cable to BCR damaged.
•
Barcode engine defect.
82
EEPROM Error, no
response from EEPROM
(located on robotic
controller)
Retry operation; after
several occurrences contact
technical support
Robotic probably defect
•
Robotic controller not working
(hardware problem, EEPROM
defect).
83
Robotic controller generic
problem
Reset the unit and retry
operation. After several
occurrences contact
technical support
Robotic probably defect
•
Robotic hardware not working
(cables, distribution boards,
robotics controller).
84
Setting of gripper motor
parameters failed
Reset the unit and retry
operation. After several
occurrences contact
technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
85
Setting of slider motor
parameters failed
Reset the unit and retry
operation. After several
occurrences contact
technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
86
Setting of elevator motor
parameters failed
Reset the unit and retry
operation. After several
occurrences contact
technical support
Robotic probably defect
•
Elevator distribution board
defect.
•
Cabling incorrect.
87
Setting of rotation motor
parameters failed
Reset the unit and retry
operation. After several
occurrences contact
technical support
Robotic probably defect
•
Robotics controller defect.
88
Setting of sled motor
parameters failed
Reset the unit and retry
operation. After several
occurrences contact
technical support
Robotic probably defect
•
Robotics controller defect.
89
Gripper blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Robotic probably defect
•
Gripper motor not connected or
defect.
•
Gripper motor voltage to low.
•
Robotics controller or
distribution boards defect.
•
Check gripper mechanism
according stiffness in movement.