5-4
u
Troubleshooting
F
AULT
S
YMPTOM
C
ODES
(FSC)
0401
Invalid Display Char
Press Enter to Clear
Firmware err - SOFT fault - width spec of %d
or %x format was outside the range {1…9} in
a lcdPrintf call.
F
0402
Invalid Display Line
Press Enter to Clear
Firmware err - SOFT fault - an lcdPrintf()
request was made to print to a non-existent
display line (outside{0..3} range).
F
0501
Barcode Comm.
Error
Enter to Reboot or
Power Down to Clear
HARD fault - Unable to open the barcode serial
port. The loopback test of the baud rate divisor
registers or one of the "expected 0" bit tests
failed. It is not necessary that a bar code scan-
ner be connected for this fault to be reported.
C, D, G
0601
Clock Init. Error
Enter to Reboot or
Power Down to Clear
HARD fault - the real time clock chip would
not initialize (never reported in any
library/loader code)
C, D, G
0602
LP-RAM Init. Error
Enter to Reboot or
Power Down to Clear
HARD fault - the low power RAM failed the
integrity test prior to initialization.
C, D, G
0603
Clock Download
Error
Press Enter to Clear
SOFT fault - The initialization of the real
time clock via the trace serial port failed.
F
0701
Slv. Comm Open
Error
Enter to Reboot or
Power Down to Clear
HARD fault - Unable to open the barcode
serial port. The loopback test of the baud
rate divisor registers or one of the "expected
0" bit tests failed.
C, D, G
0801
Not In Br. Menu
Mode
Press Enter to Clear
SOFT fault - A command sequence error was
detected. The Web TLC must command the
library to "menu mode" before it will accept
most commands. This is an automatic
feature of the Web TLC code.
F
0802
Invalid Novram Upd.
Press Enter to Clear
SOFT fault - the Web TLC command to
update the novram contained an
unrecognized post update action. The
novram has been updated but the extra
action has not occurred.
F
0803
Executing Immed.
Cmd
Press Enter to Clear
SOFT fault - The loader was completing an
immediate command when a new browser
(Web TLC) request was made. The new
request has been rejected.
F
1001
SCSI Firmware
Error
Press Enter to Clear
SOFT fault - an internal firmware error has
been detected in the SCSI process.
F
Table 5-2. Fault Symptom Codes
Summary of Contents for LXLS10
Page 1: ......
Page 4: ...xii u Preface PREFACE...
Page 8: ...iv TABLE OF CONTENTS CONT D...
Page 10: ...x LIST OF TABLES CONT D...
Page 18: ...1 6 u Introduction TAPE CARTRIDGE MAGAZINE...
Page 86: ...A 4 u Specifications SPECIFICATIONS Declaration of Conformity...
Page 90: ...Index 2 INDEX...