SECTION 3 - MACHINE CONTROLS, INDICATORS, AND OPERATION
31215918
3-7
Ground Emergency Stop Switch
A red two-position emergency stop switch when posi
-
tioned to ON with the key selector switch positioned
to ground furnishes operating power to the ground
control station key switch. In addition, the switch can
be used to turn off power to the function controls in
the event of an emergency. Turn on power by pulling
out the switch. Turn off power by depressing switch.
Hourmeter
The Hourmeter indicates the number of hours the
machine has been operated
.
Overload Indicator (LSS)
The Overload Indicator indicates when the platform
has been overloaded. An audible alarm will also signal
when the platform is overloaded.
NOTE:
If the Overload Indicator is illuminated, further
elevation will be prevented. Reduce the weight
in the platform to not exceed the rated workload indicated on
the capacity decal, then the controls will work again.
NOTE:
When ambient temperatures are below freezing, the LSS will
have a reduction in available capacity. This will trigger the LSS
before achieving the maximum allowable capacity.