SECTION 6 - JLG CONTROL SYSTEM
6-42
– JLG Lift –
3121659
FUNCTION PROBLEM - TOWER
LIFT UP PERMANENTLY
SELECTED
2257
Machine is in Platform Mode;
The Tower Lift Up switch input = High at Startup
The UGM shall prohibit Tower
Lift Up and Down
The Tower Lift In switch input = Low;
Tower Lift Up and Down permitted after
controls are initialized
FUNCTION PROBLEM - TOWER
LIFT DOWN PERMANENTLY
SELECTED
2258
Machine is in Platform Mode;
The Tower Lift Down switch input = High at Startup
The UGM shall prohibit Tower
Lift Up and Down
The Tower Lift Down switch input = Low;
Tower Lift Up and Down permitted after
controls are initialized
FUNCTION PROBLEM - PLAT-
FORM LEVEL UP PERMANENTLY
SELECTED
2262
Machine is in Platform Mode;
The Platform Level Up switch input = High at Startup
The UGM shall prohibit Plat-
form Level Up and Down
The Platform Level Up switch input = Low;
Platform Level Up and Down permitted
after controls are initialized
FUNCTION PROBLEM - PLAT-
FORM LEVEL DOWN PERMA-
NENTLY SELECTED
2263
Machine is in Platform Mode;
The Platform Level Down switch input = High at Startup
The UGM shall prohibit Plat-
form Level Up and Down
The Platform Level Down switch input =
Low;
Platform Level Up and Down permitted
after controls are initialized
FUNCTION PROBLEM - DOS
OVERRIDE PERMANENTLY
SELECTED
2264
Machine is in Platform Mode;
The DOS Override switch input = High at Startup
No response required for this
DTC
The DOS Override switch input = Low
FUNCTION PROBLEM - SOFT
TOUCH / SKYGUARD OVERRIDE
PERMANENTLY SELECTED
2286
[(MACHINE SETUP > SKYGUARD = YES) or (MACHINE SETUP >
SOFT TOUCH = YES)];
Machine is in Platform Mode;
The Soft Touch / SkyGuard Override switch input = High at
Startup
No response required for this
DTC
The Soft Touch / SkyGuard Override switch
input = Low
FUNCTION SWITCHES FAULTY -
CHECK DIAGNOSTICS/BOOM
234
The UGM detects one of the following conditions (continuous
monitoring):
The machine is in Ground Mode and both direction inputs of
the following boom controls are engaged at the same time:
Engine Start/Aux, Telescope, Platform Level, Platform Rotate,
Jib Lift, Tower Lift, Lift, or Swing.
The machine is in Platform Mode and both direction inputs of
the following boom controls are engaged at the same time:
Engine Start/Aux, Telescope, Platform Level, Platform Rotate,
Jib Lift (MACHINE SETUP > JIB = YES), Tower Lift (340AJ,
450AJ); or for Drive Mode – Max Speed/Max Torque
Disable whichever boom
functions whose boom con-
trol inputs are triggering the
fault. If Engine Start/Aux at
fault, disable Engine Start but
permit Auxiliary Power/
Emergency Descent.
None of the boom controls that trigger this
fault have both of their direction inputs
engaged at the same time
FUNCTION SWITCHES LOCKED -
SELECTED BEFORE AUX POWER
235
The UGM detects one of the following conditions:
The machine is in Ground Mode and the engine is stopped and
the ground APU/Function Enable switch becomes engaged
while a Ground control input is already engaged.
The machine is in Platform Mode and the engine is stopped
and the platform APU/Auxiliary Descent switch becomes
engaged while a Platform control input is already engaged.
The UGM not enable Auxiliary
Power/ Emergency Descent
mode
The applicable APU/Auxiliary Descent
switch is disengaged or all applicable con-
trol inputs become disengaged or the
engine state becomes ENGINE RUNNING
FUNCTION SWITCHES LOCKED -
SELECTED BEFORE START
SWITCH
236
The UGM detects one of the following conditions:
The machine is in Ground Mode and the engine is stopped and
any configured boom control is already engaged and the
ground start switch changes from not engaged to engaged
The machine is in Platform Mode and the engine is stopped
and any drive/steer or configured boom control is already
engaged and the footswitch is not engaged and the platform
start switch changes from not engaged to engaged
The UGM shall prohibit
Engine Start
The selected station’s start switch is no lon-
ger engaged
START SWITCH LOCKED -
SELECTED BEFORE KEYSWITCH
237
The start switch for the selected station is engaged during the
UGM startup sequence
The UGM shall prohibit
Engine Start
The selected station’s start switch is no lon-
ger engaged
Table 6-5. Diagnostic Trouble Code Chart
Help Message
DTC
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met unless
stated otherwise)
Required Control
Response or State
Assignment
Conditions Required for Movement
and/or to Clear Fault
Summary of Contents for JLG 450AJ
Page 2: ......
Page 32: ...SECTION 1 SPECIFICATIONS 1 18 JLG Lift 3121659 NOTES...
Page 80: ...SECTION 4 BOOM PLATFORM 4 2 JLG Lift 3121659 Figure 4 1 Boom Assembly...
Page 81: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 3 Figure 4 2 Main Boom Assembly Sheet 1 of 2...
Page 82: ...SECTION 4 BOOM PLATFORM 4 4 JLG Lift 3121659 Figure 4 3 Main Boom Assembly Sheet 2 of 2...
Page 83: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 5 Figure 4 4 Upper Boom Assembly...
Page 84: ...SECTION 4 BOOM PLATFORM 4 6 JLG Lift 3121659 Figure 4 5 Jib Assembly...
Page 118: ...SECTION 4 BOOM PLATFORM 4 40 JLG Lift 3121659 NOTES...
Page 156: ...SECTION 5 BASIC HYDRAULIC INFORMATION HYDRAULIC SCHEMATICS 5 38 JLG Lift 3121659 NOTES...
Page 164: ...SECTION 6 JLG CONTROL SYSTEM 6 8 JLG Lift 3121659 Figure 6 2 Tilt Sensor Location...
Page 169: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 13 Figure 6 7 Analyzer Connecting Points...
Page 181: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 25 Figure 6 19 Platform Module Sheet 1 of 2...
Page 182: ...SECTION 6 JLG CONTROL SYSTEM 6 26 JLG Lift 3121659 Figure 6 20 Platform Module Sheet 2 of 2...
Page 224: ...SECTION 6 JLG CONTROL SYSTEM 6 68 JLG Lift 3121659 NOTES...
Page 340: ...SECTION 7 BASIC ELECTRICAL INFORMATION ELECTRICAL SCHEMATICS 7 116 JLG Lift 3121659 NOTES...
Page 341: ......