SECTION 6 - JLG CONTROL SYSTEM
3121659
– JLG Lift –
6-57
AUXILIARY LIFT DOWN VALVE -
OPEN CIRCUIT
33538 The UGM detects an open circuit at this output
The UGM shall suspend Aux
Lift Down;
Aux Lift Down permitted
after controls are initialized
The UGM no longer detects open circuit
AUXILIARY LIFT DOWN VALVE -
SHORT TO BATTERY
33539 The UGM detects a short to battery at this output
The UGM shall prohibit
Aux Lift Down;
The UGM shall open the Aux-
iliary low side FET
Power Cycled
AUXILIARY TOWER LIFT DOWN
VALVE - SHORT TO GROUND
33540 The UGM detects a short to ground at this output
The UGM shall prohibit Aux
Tower Lift Down
Power Cycled
AUXILIARY TOWER LIFT DOWN
VALVE - OPEN CIRCUIT
33541 The UGM detects an open circuit at this output
The UGM shall suspend Aux
Tower Lift Down;
Aux Tower Lift Down permit-
ted after controls are initial-
ized
The UGM no longer detects open circuit
OSCILLATING AXLE #1 VALVE -
SHORT TO GROUND
33543 The UGM detects a short to ground at this output
UGM shall disable Oscillating
Axle #1 valve and Oscillating
Axle #2 valve outputs;
The UGM shall Lock the Oscil-
lating Axle
Power Cycled
OSCILLATING AXLE #1 VALVE -
OPEN CIRCUIT
33544 The UGM detects an open circuit at this output
UGM shall disable Oscillating
Axle #1 valve and Oscillating
Axle #2 valve outputs;
The UGM shall Lock the Oscil-
lating Axle
Power Cycled
OSCILLATING AXLE #1 VALVE -
SHORT TO BATTERY
33545 The UGM detects a short to battery at this output
UGM shall disable Oscillating
Axle #1 valve and Oscillating
Axle #2 valve outputs;
The UGM shall Lock the Oscil-
lating Axle
Power Cycled
OSCILLATING AXLE #2 VALVE -
SHORT TO GROUND
33546 The UGM detects a short to ground at this output
UGM shall disable Oscillating
Axle #1 valve and Oscillating
Axle #2 valve outputs;
The UGM shall Lock the Oscil-
lating Axle
Power Cycled
OSCILLATING AXLE #2 VALVE -
OPEN CIRCUIT
33547 The UGM detects an open circuit at this output
UGM shall disable Oscillating
Axle #1 valve and Oscillating
Axle #2 valve outputs;
The UGM shall Lock the Oscil-
lating Axle
Power Cycled
OSCILLATING AXLE #2 VALVE -
SHORT TO BATTERY
33548 The UGM detects a short to battery at this output
UGM shall disable Oscillating
Axle #1 valve and Oscillating
Axle #2 valve outputs;
The UGM shall Lock the Oscil-
lating Axle
Power Cycled
Table 6-5. Diagnostic Trouble Code Chart
Help Message
DTC
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met unless
stated otherwise)
Required Control
Response or State
Assignment
Conditions Required for Movement
and/or to Clear Fault
Summary of Contents for JLG 450AJ
Page 2: ......
Page 32: ...SECTION 1 SPECIFICATIONS 1 18 JLG Lift 3121659 NOTES...
Page 80: ...SECTION 4 BOOM PLATFORM 4 2 JLG Lift 3121659 Figure 4 1 Boom Assembly...
Page 81: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 3 Figure 4 2 Main Boom Assembly Sheet 1 of 2...
Page 82: ...SECTION 4 BOOM PLATFORM 4 4 JLG Lift 3121659 Figure 4 3 Main Boom Assembly Sheet 2 of 2...
Page 83: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 5 Figure 4 4 Upper Boom Assembly...
Page 84: ...SECTION 4 BOOM PLATFORM 4 6 JLG Lift 3121659 Figure 4 5 Jib Assembly...
Page 118: ...SECTION 4 BOOM PLATFORM 4 40 JLG Lift 3121659 NOTES...
Page 156: ...SECTION 5 BASIC HYDRAULIC INFORMATION HYDRAULIC SCHEMATICS 5 38 JLG Lift 3121659 NOTES...
Page 164: ...SECTION 6 JLG CONTROL SYSTEM 6 8 JLG Lift 3121659 Figure 6 2 Tilt Sensor Location...
Page 169: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 13 Figure 6 7 Analyzer Connecting Points...
Page 181: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 25 Figure 6 19 Platform Module Sheet 1 of 2...
Page 182: ...SECTION 6 JLG CONTROL SYSTEM 6 26 JLG Lift 3121659 Figure 6 20 Platform Module Sheet 2 of 2...
Page 224: ...SECTION 6 JLG CONTROL SYSTEM 6 68 JLG Lift 3121659 NOTES...
Page 340: ...SECTION 7 BASIC ELECTRICAL INFORMATION ELECTRICAL SCHEMATICS 7 116 JLG Lift 3121659 NOTES...
Page 341: ......