SECTION 6 - JLG CONTROL SYSTEM
6-52
– JLG Lift –
3121659
TOWER LIFT DOWN VALVE –
SHORT TO GROUND
33109 The UGM detects a short to ground at this output
The UGM shall prohibit Tower
Lift Up and Down
Power Cycled
TOWER LIFT DOWN VALVE –
OPEN CIRCUIT
33110
The UGM detects an open circuit at this output
The UGM shall suspend Tower
Lift Up and Down command
and revert to Open Loop Cur-
rent control for Tower Lift;
The UGM shall prohibit Tower
Lift Up;
The UGM shall limit Tower Lift
Down to Creep speed after
controls initialized
The UGM no longer detects open circuit;
Tower Lift Up permitted after controls are
initialized;
Full speed Tower Lift Down permitted after
controls are initialized
SWING RIGHT VALVE – SHORT
TO GROUND
33118 The UGM detects a short to ground at this output
The UGM shall prohibit Swing
Left and Right
Power Cycled
SWING RIGHT VALVE – OPEN
CIRCUIT
33119 The UGM detects an open circuit at this output
The UGM shall suspend Swing
Left and Right command and
revert to Open Loop Current
control for Swing;
The UGM shall limit Swing
Left and Right to Creep speed
after controls initialized
The UGM no longer detects open circuit;
Full speed Swing Left and Right permitted
after controls are initialized
TELESCOPE IN VALVE – SHORT
TO BATTERY
33120 The UGM detects a short to battery at this output
The UGM shall prohibit Tele-
scope In, Out and Flow Con-
trol
Power Cycled
SWING LEFT VALVE – SHORT TO
GROUND
33122 The UGM detects a short to ground at this output
The UGM shall prohibit Swing
Left and Right
Power Cycled
TELESCOPE OUT VALVE –
SHORT TO BATTERY
33123 The UGM detects a short to battery at this output
The UGM shall prohibit Tele-
scope In, Out and Flow Con-
trol
Power Cycled
LIFT VALVES – SHORT TO BAT-
TERY
33182 The UGM detects a short to battery at either the Lift Up or Lift
Down valve
The UGM shall prohibit Lift Up
and Down;
The UGM shall open the Lift
Current Feedback low side
FET
Power Cycled
TELESCOPE OUT VALVE – OPEN
CIRCUIT
33186 The UGM detects an open circuit at this output
(340AJ, 400S, 450AJ)
The UGM shall suspend Tele-
scope In and Out
(18RS, 24RS) The UGM shall
suspend Telescope In and Out
command and revert to Open
Loop Current control for Tele-
scope
The UGM shall limit Telescope
In and Out to Creep speed
after controls initialized
The UGM no longer detects open circuit;
Full speed Telescope In and Out permitted
after controls are initialized
TELESCOPE OUT VALVE –
SHORT TO GROUND
33188 The UGM detects a short to ground at this output
The UGM shall prohibit Tele-
scope Out;
Tele In speed limited to Creep
Power Cycled
Table 6-5. Diagnostic Trouble Code Chart
Help Message
DTC
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met unless
stated otherwise)
Required Control
Response or State
Assignment
Conditions Required for Movement
and/or to Clear Fault
Summary of Contents for JLG 450AJ
Page 2: ......
Page 32: ...SECTION 1 SPECIFICATIONS 1 18 JLG Lift 3121659 NOTES...
Page 80: ...SECTION 4 BOOM PLATFORM 4 2 JLG Lift 3121659 Figure 4 1 Boom Assembly...
Page 81: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 3 Figure 4 2 Main Boom Assembly Sheet 1 of 2...
Page 82: ...SECTION 4 BOOM PLATFORM 4 4 JLG Lift 3121659 Figure 4 3 Main Boom Assembly Sheet 2 of 2...
Page 83: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 5 Figure 4 4 Upper Boom Assembly...
Page 84: ...SECTION 4 BOOM PLATFORM 4 6 JLG Lift 3121659 Figure 4 5 Jib Assembly...
Page 118: ...SECTION 4 BOOM PLATFORM 4 40 JLG Lift 3121659 NOTES...
Page 156: ...SECTION 5 BASIC HYDRAULIC INFORMATION HYDRAULIC SCHEMATICS 5 38 JLG Lift 3121659 NOTES...
Page 164: ...SECTION 6 JLG CONTROL SYSTEM 6 8 JLG Lift 3121659 Figure 6 2 Tilt Sensor Location...
Page 169: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 13 Figure 6 7 Analyzer Connecting Points...
Page 181: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 25 Figure 6 19 Platform Module Sheet 1 of 2...
Page 182: ...SECTION 6 JLG CONTROL SYSTEM 6 26 JLG Lift 3121659 Figure 6 20 Platform Module Sheet 2 of 2...
Page 224: ...SECTION 6 JLG CONTROL SYSTEM 6 68 JLG Lift 3121659 NOTES...
Page 340: ...SECTION 7 BASIC ELECTRICAL INFORMATION ELECTRICAL SCHEMATICS 7 116 JLG Lift 3121659 NOTES...
Page 341: ......