SECTION 6 - JLG CONTROL SYSTEM
6-28
– JLG Lift –
3121659
STARTER LOCKOUT:
6*
1
2
DISABLED: Automatic pre-glow time determined by ambient air temperature; engine start
can be attempted at any time during pre-glow.
ENABLED: Automatic pre-glow time determined by ambient air temperature; engine start is NOT permitted until pre-
glow is finished.
1
* This menu item is visible only if Engine Selection ≠ Dual Fuel ECM
ENGINE SHUTDOWN:
7
1
2
DISABLED: No engine shutdown.
ENABLED: Shutdown engine for high coolant temperature fault or low oil pressure fault
2
FUEL CUTOUT:
8*
1
2
3
4
ONE RESTART: One restart with limited run time when near Empty.
ENGINE STOP: No starting permitted when near Empty.
NONE
RESTART: Restarts allowed with limited run time when near Empty
4
* Visible for Engine Selection = Kubota D1105 only
TILT:
9*
1
2
3
4
5
6
5 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than
5 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 4 degrees and above
elevation; also reduces drive speed to creep.
3 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 3 degrees and above
elevation; also reduces drive speed to creep.
5 D CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 5 degrees and
above elevation; also disallows tower lift up, drive, telescope out and lift up.
4 D CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 4 degrees and
above elevation; also disallows tower lift up, drive, telescope out and lift up.
3 D CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 3 degrees and
above elevation; also disallows tower lift up, drive, telescope out and lift up.
1
* Certain market selections will limit tilt options and alter default setting.
Note:
Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform alarm when the machine is also above elevation.
JIB:
10*
1
2
NO: No jib installed.
YES: Jib installed which has up and down movements only.
2
* This menu item not visible.
Table 6-2. Machine Configuration Programming Information
Configurationn
Label/Digit
Number
Description
Default
Number
Summary of Contents for JLG 450AJ
Page 2: ......
Page 32: ...SECTION 1 SPECIFICATIONS 1 18 JLG Lift 3121659 NOTES...
Page 80: ...SECTION 4 BOOM PLATFORM 4 2 JLG Lift 3121659 Figure 4 1 Boom Assembly...
Page 81: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 3 Figure 4 2 Main Boom Assembly Sheet 1 of 2...
Page 82: ...SECTION 4 BOOM PLATFORM 4 4 JLG Lift 3121659 Figure 4 3 Main Boom Assembly Sheet 2 of 2...
Page 83: ...SECTION 4 BOOM PLATFORM 3121659 JLG Lift 4 5 Figure 4 4 Upper Boom Assembly...
Page 84: ...SECTION 4 BOOM PLATFORM 4 6 JLG Lift 3121659 Figure 4 5 Jib Assembly...
Page 118: ...SECTION 4 BOOM PLATFORM 4 40 JLG Lift 3121659 NOTES...
Page 156: ...SECTION 5 BASIC HYDRAULIC INFORMATION HYDRAULIC SCHEMATICS 5 38 JLG Lift 3121659 NOTES...
Page 164: ...SECTION 6 JLG CONTROL SYSTEM 6 8 JLG Lift 3121659 Figure 6 2 Tilt Sensor Location...
Page 169: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 13 Figure 6 7 Analyzer Connecting Points...
Page 181: ...SECTION 6 JLG CONTROL SYSTEM 3121659 JLG Lift 6 25 Figure 6 19 Platform Module Sheet 1 of 2...
Page 182: ...SECTION 6 JLG CONTROL SYSTEM 6 26 JLG Lift 3121659 Figure 6 20 Platform Module Sheet 2 of 2...
Page 224: ...SECTION 6 JLG CONTROL SYSTEM 6 68 JLG Lift 3121659 NOTES...
Page 340: ...SECTION 7 BASIC ELECTRICAL INFORMATION ELECTRICAL SCHEMATICS 7 116 JLG Lift 3121659 NOTES...
Page 341: ......