![ORiNG TRGPS-9084GT-M12X-BP2-MV User Manual Download Page 101](http://html.mh-extra.com/html/oring/trgps-9084gt-m12x-bp2-mv/trgps-9084gt-m12x-bp2-mv_user-manual_1652005101.webp)
TRGPS-9084GT-M12X-BP2-MV User
Manual
ORing Industrial Networking Corp
100
Label
Description
Mode
Indicates the device binding operation for each port. Possible modes
are:
---
: disable
Scan
: scans IP/MAC automatically, but no binding function
Binding
: enables binding. Under this mode, any IP/MAC that does
not match the entry will not be allowed to access the network.
Shutdown
: shuts down the port (No Link)
Alive Check
Active
Check to enable alive check. When enabled, switch will ping the
device continually.
Alive Check
Status
Indicates alive check status. Possible statuses are:
---
: disable
Got Reply
: receive ping reply from device, meaning the device is still
alive
Lost Reply
: not receiving ping reply from device, meaning the device
might have been dead.
Stream Check
Active
Check to enable stream check. When enabled, the switch will detect
the stream change (getting low) from the device.
Stream Check
Status
Indicates stream check status. Possible statuses are:
---
: disable
Normal
: the stream is normal.
Low
: the stream is getting low.
DDoS Prevention
Acton
Check to enable DDOS prevention. When enabled, the switch will
monitor the device against DDOS attacks.
DDoS Prevention
Status
Indicates DDOS prevention status. Possible statuses are:
---
: disable
Analyzing
: analyzes packet throughput for initialization
Running
: analysis completes and ready for next move