RDS-3086/3166G User Manual
ORing Industrial Networking Corp
32
Label
Description
Data Encryption
Click
Enable
and the data will be encrypted with SSL.
TCP Server Port
Set the port number for data transmission.
Idle Timeout
When serial port stops data transmission for a defined period of
time (Idle Timeout), the connection will be closed and the port
will be freed and try to connect with other hosts.
0
indicate
disable this function. Factory default value is
0
. If Multilink is
configured, only the first host connection is effective for this
setting.
Alive Check
The serial device will send TCP alive-check package in each
defined time interval (Alive Check) to remote host to check the
TCP connection. If the TCP connection is not alive, the
connection will be closed and the port will be freed.
0
indicate
disable this function. Factory default is
0
.
Max Connection
The number of maximum connections can be supported. The
maximum value is
5
, default values is
1
.
TCP Client Mode
In TCP Client Mode, the device can establish a TCP connection with the server by the
method you set (Startup or any character). After the data has been transferred, the
device can disconnect automatically from the server by using the TCP alive check time or
idle timeout settings.