![ORiNG RDS-3086 User Manual Download Page 21](http://html1.mh-extra.com/html/oring/rds-3086/rds-3086_user-manual_1651765021.webp)
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
20
delimiters for Serial to Ethernet and / or Ethernet to Serial
communications. You can define max. 4 delimiters
(00~FF, Hex) for each way. The data will be hold until the
delimiters are received or the option.
Flush Serial to Ethernet data buffer
times out.
0
means
disable. Factory default is
0
.
Flush Data Buffer After:
The received data will be queuing in the buffer until all the
delimiters are matched. When the buffer is full (4K Bytes) or
after "
flush S2E data buffer
" timeout the data will also be sent.
You can set the time from 0 to 65535 seconds.
Force TX Interval Time
Force TX interval time is to specify the timeout when no data
has been transmitted. When the timeout is reached or TX buffer
is full (4K Bytes), the queued data will be sent.
0
means
disable. Factory default value is
0
.
4.1.4.2 Service Mode
Virtual COM Mode
In Virtual COM Mode, the driver establishes a transparent connection between host and serial
device by mapping the port of the serial server serial port to a local COM port on the host
computer. Virtual COM Mode also supports up to 5 simultaneous connections, so that multiple
hosts can send or receive data by the same serial device at the same time.