RDS-3086/3166G User Manual
ORing Industrial Networking Corp
23
connection will be closed and the port will be freed.
0
means the
function is disabled which is the factory default value
.
Max Connection
The number of maximum connections can be support
simultaneously is
5
; default values is
1
.
Destination Host
Input the IP address of the host.
TCP Client Mode
In TCP Client mode, the device can establish a TCP connection with the server by the method
you have settled (Startup or any character). After the data has been transferred, the device can
disconnect automatically from the server by using the TCP alive check time or idle time
settings.
Label
Description
Destination Host
Input the IP address of the host.
Port
Set the port number of data port.
Idle Timeout
When a serial port stops data transmission for a defined period of
time (Idle Timeout), the connection will be closed and the port will
be freed and try to connect with other hosts.
0
means the function
is disabled which is the factory default value. If multilink is
configured, only the first host connection is effective for this setting.