6.4.3
Inserting adapter clamping shell
1. Install the adapter clamping shell into the body. The cavity of the clamping
shell should thereby be flush with the cavity of the RPG 2.5-body (see
arrow).
2. Screw in the adapter clamping shell with the clamping shell retainers (small
handles) (2).
3. Press on the clamping shell slightly and install it into the adapter clamping
shell.
The Orbitalum logo should cover the clamping shell with the point marked in
red on the body (see arrows below).
4. Screw in the clamping shell with the clamp handle (large handle) (3).
The clamping shell has been correctly installed, if it is locked in place. If the
clamp shell is not locked, this can be rectified by a gentle turn of the clamp
shell.
The clamping shell has now been installed correctly.