6 Operation
Operating instructions RPG ONE, RPG 1.5, RPG 2.5
24
(02.10)
MT_RPG ONE, RPG 1.5, RPG 2.5_BA_04_790036766_00.doc
orbitalum tools
gmbh
Tool breakage
Using the adapter clamping shell could lead to collisions with the tool.
X
Take care that there is enough space between the tool and the adapter
clamping shell.
6.5
Clamping the tube
Risk to life due to tilting machine and/or tilting tube
Non-observance could result in death or critical injury.
X
Support long tubes with suitable fixtures.
Tool breakage
A multifunctional tool can be damaged by incorrectly setting up the tube.
X
Before clamping the tube, take care that there is enough space between
the MFW and the tube.
X
Clamp the tube squarely, ensuring that the tube and machine axes are
aligned. If care is not taken, the tube end may not be processed at right
angles.
1. Set up the tube in the clamping shell of RPG or with the use of a
RPG Cordless, guide the machine to the tube and pick it up with the
clamping shell.
2. To clamp the tube tightly, rotate the clamp handle (large handle) (1)
clockwise until stop.
Clamp tube with RPG Electric:
tube to machine
Clamp tube with RPG Cordless:
machine to tube
The tube can be processed now.
ATTENTION
DANGER
ATTENTION
Note
1
1