Operating instructions RPG ONE, RPG 1.5, RPG 2.5
6 Operation
orbitalum tools
gmbh
(02.10)
MT_RPG ONE, RPG 1.5, RPG 2.5_BA_04_790036766_00.doc
25
X
To remove the tube from the machine, rotate the clamp handle (large
handle) (1) anti-clockwise up to the stop.
6.6
Selecting the speed range
There are 2 speed levels in the RPG drives.
It is recommended that you work exclusively with speed level 1.
RPG ONE and RPG 1.5: disabled speed level 2 upon delivery.
Type of machine
Speed range level 1 [min
–1
]
Speed range level 2 [min
–1
]
RPG ONE
145 - 380
(disabled)
RPG ONE Cordless
0 - 400
(disabled)
RPG 1.5
145 - 380
(disabled)
RPG 1.5 Cordless
0 - 400
(disabled)
RPG 2.5
9 - 52
27 - 153
RPG 2.5 Cordless
0 - 24
0 - 83
6.6.1
Adjusting the speed: RPG Electric
The chip removal characteristic may be influenced by the speed.
The speed level can be pre-installed using the speed regulator (1) in the
RPG Electric. The outer diameter of the tube can be adjusted precisely using
the thumb wheel (2):
Speed regulator (1) level codes
Tortoise
Level 1
9 - 52 min
–1
Hare
Level 2
27 - 153 min
–1
Fine-tuning of the thumb wheel speed regulator (2)
RPG ONE
RPG 1.5
RPG 2.5
Level
Tube OD
[mm]
Tube OD
[inch]
Level
Tube OD
[mm]
Tube OD
[inch]
Level
Tube OD
[mm]
Tube OD
[inch]
C
3.18 0.125
C
3.18 0.125
G
6.35 0.250
B
6.35 0.250
B
6.35 0.250
D
38.10 1.500
A
12.70 0.500
A
12.70 0.500
C
50.80 2.000
A
25.40 1.000
A
38.10 1.500
B
63.50 2.500
X
Increase speed using thumb wheel (2).
X
Decrease speed using thumb wheel (2).
Note
Increasing speed
Decreasing speed
Tortoise
level 1
1
2
Hare
level 2