Chapter 4
Servicing Motherboard Components
4-11
■
Section 4.2.2, “Installing the Air Duct” on page 4-13
You must remove the air duct when removing and installing the following
components:
■
Power distribution board
■
Power supply unit (PSU) PDB
■
Paddle card
■
Motherboard
Note –
CRU
: This customer replaceable unit can be replaced by anyone.
Caution –
To prevent the system from overheating, ensure that the air duct is
correctly installed before powering on the server.
4.2.1
Removing the Air Duct
1. Prepare the server for service.
a. Power off the server.
See
Section 2.5, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.5, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.6, “Extending the Server to the Maintenance Position” on
page 2-6
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Slide the air duct to the right to disengage the left hand pin as shown in
FIGURE 4-6
.
3. Slide the air duct to the left to disengage the right hand pin.
4. Move the air duct towards the back to clear the lip on the midwall.
Summary of Contents for Sun Fire X4240
Page 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Page 9: ...Contents ix Index Index 1 ...
Page 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Page 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Page 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Page 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Page 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...