4-44
Sun Fire X4240 Server Service Manual • September 2010
b. Slide the server into the the rack.
See
Section 6.3, “Returning the Server to the Normal Rack Position” on
page 6-4
.
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.
NVRAM is cleared.
4.10
Recovering From Corrupt Service
Processor Software
If the SP (service processor) software becomes corrupted, you can reinstall the default
SP software image from the Tools and Drivers CD.
You need:
■
The Tools and Drivers CD.
■
A bootable USB flash device.
■
A jumper cap. The server has a jumper cap installed on the motherboard, next to
the AST 2000 chip.
4.10.1
Reinstalling The Default SP Software Image From
The Tools And Drivers CD
This emergency flash recovery procedure returns the SP to a default configuration.
The ILOM SPBIOS <
file-name
>
.pkg
file format (for example
ilom.X4150-2.0.2.6.pkg
) cannot be used for emergency recovery. Use the
<
file-name
>
.bin
recovery image instead.
1. Copy the following SP files from the Tools and Drivers CD, located in the
recovery
directory, to a USB bootable flash device.
■
SOCFLASH.EXE
■
DOS4GW
Summary of Contents for Sun Fire X4240
Page 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Page 9: ...Contents ix Index Index 1 ...
Page 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Page 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Page 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Page 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Page 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...