Sun Fire X4240 Server Service Manual • September 2010
4.1
Servicing DIMMs
This section describes how to diagnose and replace faulty DDR2 (Double-Data Rate)
DIMMs . The following topics are covered:
■
Section 4.1.1, “Identifying Faulty DIMMs” on page 4-2
■
Section 4.1.2, “DDR2 DIMM Guidelines” on page 4-4
■
Includes additional DDR2 DIMM information.
■
Section 4.1.3, “Removing DDR2 DIMMs” on page 4-7
■
Section 4.1.4, “Installing DDR2 DIMMs” on page 4-8
■
Section 4.1.5, “Installing Additional DDR2 DIMMs” on page 4-10
■
How to upgrade the server with additional DDR2 DIMMs.
Refer to the
Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide
for additional
DIMM troubleshooting information.
Note –
CRU
: This customer replaceable unit can be replaced by anyone.
Caution –
This procedure requires that you handle components that are sensitive to
static discharge. This sensitivity can cause the component to fail. To avoid damage,
ensure that you follow antistatic practices as described in
Section 2.8.1, “Electrostatic
Discharge Safety Measures” on page 2-10
.
4.1.1
Identifying Faulty DIMMs
The Sun Fire X4240 Service Required LED is lit if the system detects a DDR2 DIMM
fault.
To identify faulty DDR2 DIMMs:
1. Prepare the server for service.
a. Power off the server.
See
Section 2.5, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.5, “Powering Off the Server” on page 2-4
.
Summary of Contents for Sun Fire X4240
Page 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Page 9: ...Contents ix Index Index 1 ...
Page 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Page 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Page 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Page 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Page 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...