3-16
Sun Fire X4240 Server Service Manual • September 2010
FIGURE 3-10
Power Supply Status LEDs
3.4.3
Removing a Power Supply
Caution –
Hazardous voltages are present. To reduce the risk of electric shock and
danger to personal health, follow the instructions.
1. Determine which power supply (0 or 1) requires replacement.
A lit (amber) failure LED on a power supply indicates that a failure was detected.
2. Gain access to the rear of the server where the faulty power supply is located.
3. Release the cable management arm (CMA). (
FIGURE 3-11
)
The CMA is located at the rear of the server rack.
a. Press and hold the tab.
Figure Legend
Legend
LED
Symbol
Color
Lights when
1
OK to Remove
Blue
A power supply can be removed
safely during a hot–swap operation.
2
Service Required
Amber
The power supply is faulty.
The front and rear panel Service
Required LEDs are also lit if the
system detects a power supply fault.
3
AC Present
~AC
Green
The power supply is plugged in and
AC power is available, regardless of
system power state.
Summary of Contents for Sun Fire X4240
Page 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Page 9: ...Contents ix Index Index 1 ...
Page 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Page 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Page 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Page 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Page 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...