Chapter 5
Servicing Infrastructure Boards and Components
5-7
FIGURE 5-3
Removing the Hard Drive Cage
5.2.2
Installing the Hard Drive Cage
1. Connect the hard drives data cables.
Press the connector into its socket until it snaps into place.
2. Position the hard drive cage in the chassis, over its standoffs. (
FIGURE 5-4
[1])
3. Slide the hard drive cage back until the hard drive backplane engages with the
paddle card connector. (
FIGURE 5-4
[2])
4. Replace the No. 2 Phillips screws securing the hard drive cage to the chassis.
(
FIGURE 5-4
[3])
Two screws secure the disk cage to each side of the chassis.
5. Install the fan power boards.
See
Section 5.1.2, “Installing a Fan Power Board” on page 5-4
.