4-42
Sun Fire X4240 Server Service Manual • September 2010
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.
4.9
Resetting Passwords and Clearing
CMOS NVRAM
The following topics are covered:
■
Section 4.9.1, “Overview” on page 4-42
■
Section 4.9.2, “Resetting a Service Processor Password From the BIOS Screen” on
page 4-42
■
Section 4.9.3, “Resetting CMOS NVRAM Using a Jumper” on page 4-43
4.9.1
Overview
Clearing CMOS settings resets the BIOS settings, including the BIOS password. You
can reset a password from the BIOS screen or with a jumper. You can also clear the
CMOS NVRAM and BIOS password by changing jumpers as listed in
TABLE 4-2
.
4.9.2
Resetting a Service Processor Password From the
BIOS Screen
To reset a password for the Service Processor, access the BIOS Security screen.
TABLE 4-2
Sun Fire X4240 Server Jumpers
Jumper
Function
Location
J603
Clears the SP password.
Access on the motherboard in the rear next
to the SP, below PCIe slot 1, PCIe riser 1.
J1602
Clears the CMOS NVRAM
and the BIOS password.
Access on the motherboard in the rear next
to the SATA connector, below PCIe slot 0,
PCIe riser 0.
Summary of Contents for Sun Fire X4240
Page 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Page 9: ...Contents ix Index Index 1 ...
Page 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Page 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Page 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Page 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Page 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...