Chapter 4
Servicing Motherboard Components
4-3
c. Slide the server out of the rack.
See
Section 2.6, “Extending the Server to the Maintenance Position” on
page 2-6
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Press and hold the Remind button to identify which DDR2 DIMM is faulty.
(
FIGURE 4-1
)
3. Note the location of faulty DDR2 DIMMs.
Faulty DDR2 DIMMs are identified with a corresponding amber LED on the
motherboard.
4. Ensure that all DDR2 DIMMs are seated correctly in their slots.
If re-seating the DDR2 DIMM does not fix the problem, remove and replace the
faulty DDR2 DIMM.
Note –
Refer to the
Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide
for
more information about DIMM System Event Log (SEL) messages.
Summary of Contents for Sun Fire X4240
Page 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Page 9: ...Contents ix Index Index 1 ...
Page 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Page 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Page 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Page 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Page 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...