Appendix D
Troubleshooting
D-5
where
event-id
is the event ID displayed in the fault message.
Each diagnosis lists one or more fault suspects represented by fault managed
resource identifiers (FMRIs). The FMRI may represent a component in a FRU, the
FRU itself, or a bus segment within a FRU.
Note –
The letters
hc
in an error message usually refer to a
hardware component
. Look
for the string
hc:///
to identify a suspected hardware component.
The following example shows the fault diagnosis for an I
2
C access failure for the LED
controller for PSU 1:
XSCF>
fmdump -v -u 1a56dc98-aa6d-4128-adaf-428d45fcb024
TIME UUID MSG-ID
Sep 15 13:05:53.8069 1a56dc98-aa6d-4128-adaf-428d45fcb024 IOXSCF-8000-CQ
25% fault.chassis.iox.i2c.device
Problem in: hc:///iox=983555/ps=1/ledctrl=0
Affects: hc:///iox=983555/ps=1/ledctrl=0
FRU: hc://:product-id=SPARC Enterprise M4000 :chassis-id=
0000000000:server-id=burl-m4000-0:serial=DD0566:part=CF003001701\
3001701:revision=04/component=IOX@X084/PS1
Location: IOX@X084/PS1
25% fault.chassis.iox.i2c.bus
Problem in: hc:///iox=983555/iob=0/i2c_local=0
Affects: hc:///iox=983555/iob=0/i2c_local=0
FRU: hc://:product-id=SPARC Enterprise M4000 :chassis-id=
0000000000:server-id=burl-m4000-0:serial=1E0041:part=5016939:revision=
03/component=IOX@X084/IOB0
Location: IOX@X084/IOB0
25% fault.chassis.iox.i2c.bus
Problem in: hc:///iox=983555/ps=1/i2c_local=0
Affects: hc:///iox=983555/ps=1/i2c_local=0
FRU: hc://:product-id=SPARC Enterprise M4000 :chassis-id=
0000000000:server-id=burl-m4000-0:serial=DD0566:part=CF003001701\
3001701:revision=04/component=IOX@X084/PS1
Location: IOX@X084/PS1
25% fault.chassis.iox.i2c.bus
Problem in: hc:///iox=983555/i2c_a=0
Summary of Contents for SPARC Enterprise M4000