c. Unlock the PCI card from the defective carrier and install the card on the
replacement carrier.
d. If the type C lock is used, ensure that it is not located where it will hit the
card socket in the I/O boat.
9. Install the carrier in the I/O boat:
a. Pull the carrier handle into the fully open position to raise the carrier plate.
b. Carefully place the carrier in the card guides at the top and bottom of the
carrier slot in the I/O boat.
c. Press on the metal front panel of the carrier to push the carrier fully into the
carrier slot.
Caution –
Do not press the plastic carrier handle during
. If you press the
handle, the PCI card and the sliding carrier plate might suddenly fall, breaking the
plastic locator bar (
) by hitting it against the lower edge of the I/O boat.
d. Push the carrier handle into the closed position.
This action seats the PCI card in the card socket.
Caution –
If the carrier handle does not close easily, the PCI card might not be
seating properly in the card socket in the I/O boat. Remove the carrier and inspect
the PCI card. If the bottom of the PCI card is not perfectly horizontal, loosen the card
locks and realign the card on the carrier. For troubleshooting information, see
e. Lock the carrier handle into place with the carrier locking screw located on
the top of the handle.
f. Connect the I/O cable(s) to the PCI card.
10. Move the cable plate back into the normal position (
) and tighten the
cable plate locking screw(s).
11. If this is a link card, power up the link.
See
Section 4.13, “Powering Up a Link After Service” on page 4-33