A-4
External I/O Expansion Unit for SPARC Enterprise M
x
000 Servers Installation and Service Manual • April 2011
A.4
Power Source Requirements
Note –
To ensure redundant operation of the power supplies, the two power cords
should be connected to separate AC circuits.
A.5
Acoustic Noise Emissions
Note –
Declared noise emissions are in accordance with ISO 9296 standards.
Description
Specification
Input voltage range
100 VAC to 240 VAC, 50-60 Hz
Maximum input current
8.0 A at 100 VAC
4.0 A at 220 VAC
Rush current, per AC cord
30 A (peak)
Maximum input power
600 W
Phases
Single
Leakage current, per AC cord
1.5 mA or less
Description
Mode
Specification
LwAd (1 B = 10 dB)
Operating acoustic noise
Idling acoustic noise
6.7 B
6.7 B
LpAm (bystander positions)
Operating acoustic noise
Idling acoustic noise
59 dBA
59 dBA