Alarm Name
Alarm ID
Alarm
Severity
Causes
Example Log
Message
Graphic
Display
Window
Message
TEMPERATU
RE HIGH
65538
CRITICAL:
>105°C
MAJOR:
>100°C
MINOR:
>95°C
Fans are
obstructed or
stopped. The
room is
abnormally
hot.
Temperature:
XX.XXC
(where XX.XX
is the
temperature in
degrees)
Temperature X
C (where X is
the
temperature in
degrees)
If this alarm occurs, the Acme Packet 4600 turns the fan speed up to the fastest possible
speed.
Fan Speed Alarms
The following table lists the fan speed alarm.
Alarm Name
Alarm ID
Alarm
Severity
Causes
Example Log
Message
Graphic
Display
Window
Message
FAN
STOPPED
65537
CRITICAL:
any fan speed
is <50%. Or
speed of two
or more fans
is >50% and
<75%.
MAJOR:
speed of two
or more fans
is
> 75% and <
90%. Or
speed of one
fan is >50%
and <75% and
the other two
fans are at
normal speed.
MINOR:
speed of one
fan> 75% and
<90%, the
other two fans
are at normal
speed
Fan failure.
Fan speed:
XXXX XXXX
XXXX
where xxxx
xxxx xxxx is
the revolutions
per minute
(RPM) of each
fan on the fan
module
Fan stopped
If this alarm occurs, the Acme Packet 4600 turns the fan speed up to the fastest possible
speed.
Environmental Sensor Alarm
The following table lists the environmental sensor alarm.
Chapter 6
Alarms
6-34