HW ALARM : 0
LINK ALARM : 2
•
Screen 2 — System temperature and fan speeds:
–
TEMPERATURE: 38.00 C
FAN SPEEDS:
100% 100% 100% 100%
•
Screen 3 — System voltages:
–
VOLTAGES (V):
1.099, 1.186
1.488, 1.790
2.458, 3.278, 4.982
To use the ENVIRONMENT menu in the graphic display:
1.
From the top menu of the graphic display, press the Enter button.
2.
Press the Up or Down buttons to scroll to the ENVIRONMENT selection.
3.
Press the Enter button. The ENVIRONMENT information is displayed.
4.
Press the Up or Down button to scroll to the RETURN selection.
5.
Press the Enter button to return to the Top Menu.
RETURN
Pressing the Enter button for the RETURN selection returns you to the base display
during normal operating conditions or to the alarm display during an alarm condition.
Graphic Display Output for HA Nodes
The information included in this section only applies to high availability Acme Packet
4600 System nodes.
The graphic display on a Acme Packet 4600 in an HA node indicates the current HA
state. Five state indications can be displayed on the graphic display. Only the Standby
and Active state indications appear in the graphic display for more than a few seconds.
An explanation and example of each HA state follows.
Initial State Displays
The following example shows the output in the graphic display window of a Acme
Packet 4600 in the initial state:
NET - NET
SESSION DIRECTOR (I)
Out-Of-Service State Displays
The following example shows the output in the graphic display window of an out-of-
service Acme Packet 4600:
NET - NET
Chapter 3
Graphic Display Output for HA Nodes
3-6