Page
18
10.3
Controller parameters
Ecomax input/output module
Size:
215×132×83 (width×height×depth)
Supply voltage:
230VAC
Maximum current consumption:
2A
Maximum input power:
260VA
Temperature sensor input :
2 inputs for DS18B20 digital temperature sensors
Safety thermostat input:
230VAC normally closed contact
Open door sensor input:
230VAC normally closed contact
Fan motor output:
230VAC triac,
max. 40VA
Circulation pump output:
230VAC relay,
max. 100VA
Sec. circulation pump output:
230VAC, permanently closed
max. 100VA
Protection
2A blow fuse.
Protection to EN60529:
IP2X
Operating temperature:
up to 60°C
Designed to:
EN60730-1 2:2001
EMC tested to:
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5,EN 61000-4-11, EN 55022
Environment to
Č
SN 332000-3:
AA5, AB5, AD1, AE1, AF1, AK1, AM1, BA1, BE1
Intended for base of degree of combustibility: B, C1, C2 a C3.
For all conductive parts of the boiler, equipotential bonding must be performed with potential PE.
Ecomax control panel
Size:
136×72×25 (width×height×depth)
Supply voltage:
24VDC
Maximum input power:
5VA
Protection to EN60529:
IP2X
Operating temperature:
up to 60°C
Designed to:
EN60730-1 2:2001
EMC tested to:
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5,EN 61000-4-11, EN 55022
Environment to
Č
SN 332000-3:
AA5, AB5, AD1, AE1, AF1, AK1, AM1, BA1, BE1
Intended for base of degree of combustibility: B, C1, C2 a C3.
11 Disposal
No hazardous materials requesting special waste treatment were used in the making and packing of the boiler.
The packaging consists of a wooden transport pallet, a paper carton and a flexible packing foil. After the disassembly the paper
and the pallet must be burned in the boiler and the packing foil handed over to the local municipal waste landfill.
At the end of the boiler life, the same must be dismantled and the sorted material submitted to the collection yards as per
the individual types of materials and in keeping with the applicable regulations.
Used boiler material: - steel sheet
-
grey iron
-
aluminium allow in the fan body
-
glass fibre insulation
-
refractory concrete
-
synthetic or powder paint coat
-
electronic components
-
copper conductors
-
silicon conductor insulation