Technical parameters 

 
 
 
 
Boiler type 
 

       
    ECOMAX 25 

      
   ECOMAX 35 

  
   ECOMAX 42 

Nominal power 

  kW 

25 

35 

42 

Chute volume 

 Dm

120 

170 

200 

Water volume 

 Dm

3

 

60 

68 

78 

Outlet branch diameter 

 mm 

160 

160 

160 

Maximum boiler width 

 mm 

612 

612 

712 

Maximum boiler depth 

 mm 

850 

1000 

1120 

Maximum boiler height 

  mm 

1200 

1200 

1475 

Chute depth 

  mm 

500 

500 

650 

Maximum log diameter 

  mm 

220 

220 

220 

Maximum log length 

  mm 

300 

500 

500 

Operating chimney draught 

  Pa 

20-25 

20-25 

20-25 

Maximum working overpressure 

  kPa 

200 

200 

200 

Maximum noise level 

  dB 

65 

65 

65 

Efficiency 

   % 

83 

81 

79 

Mass 

   kg 

270 

360 

454 

Operating voltage 

   V/Hz 

230/50 

230/50 

230/50 

Electric power requirement 

   W 

21 

21 

41 

Electric power requirement with electronic 
control 

   W 

30 

30 

50 

Protection 

 

IP 20 

IP 20 

IP 20 

 

 

 

 

 

Nominal power and efficiency were measured at 11% firewood humidity 
 

 
5. Fuel material 

 
The  fuel  material  specified  is  lump  wood.  No  wood  quality  is  specified.  It  is  recommended  to  burn  lump  wood  cut  in  maximum 
lengths  as  per  the  table  of  technical  parameters.  The  wood  must  be  combusted  as  dry as  possible,  with  at  least  15%  humidity 
max. Damp wood releases water when combusted, which then condensates on the walls of the boiler body and the chimney. This 
results in the emergence of aggressive substances which markedly reduce the boiler and chimney life. Burning damp wood also 
results in a marked boiler power reduction. 

 

Indicative table of the calorific value of wood mass depending on the water content 
 
              
Humidity 

                                       Calorific value     

( kWh/kg) 

    (%) 

              Coniferous 

       Deciduous 

15 

4.329 

4.057 

20 

4.035 

3.779 

25 

3.740 

3.500 

30 

3.446 

3.222 

35 

3.151 

2.943 

40 

2.856 

2.664 

45 

2.562 

2.386 

50 

2.267 

2.107 

55 

1.973 

1.829 

60 

1.678 

1.550 

 

6.  Accessories 

 

The following accessories are supplied along with the boiler: 
 
Steel brush 

1 unit 

 

Screw M8 x 25 

 

8 units  Filling valve   

 

1 unit 

Scraper 

1 unit 

 

Nut M8   

 

8 units  Gasket   

 

2 units 

Discharge fan  1 unit  

 

Washer 8.2 

 

8 units  Warranty Certificate  

1 item 

Counterflanges 2 units 

 

Operating Manual  

1 item 

Summary of Contents for ECOMAX 25kW

Page 1: ...Page 1 HOT WATER WOOD BOILER ECOMAX 25 35 42kW USER MANUAL 2012 Manufacturer...

Page 2: ...ection to the hot water system 7 7 3 Boiler connection to the smoke duct and chimney 9 7 4 Boiler connection to the power grid 9 8 Operating and maintaining the boiler 10 8 1 General principles 10 8 2...

Page 3: ...ee B C1 and C2 combustibility materials for the degrees of combustibility see the Table The safe distance of 200 mm must be doubled for any boiler and smoke flues located in the vicinity of C3 degree...

Page 4: ...idential spaces including corridors Warning In circumstances resulting in the risk of temporary ingress of combustible gases or vapours and while performing works that might imply a temporary risk of...

Page 5: ...or 3 Chute 12 4 Combustion chamber 5 Chimney dumper 14 15 6 Door screen 7 Hot water branch 8 Cold water branch 9 Door closing 10 Control unit 11 Main switch 12 Safety valve branches 13 Cleaning cap 14...

Page 6: ...wood quality is specified It is recommended to burn lump wood cut in maximum lengths as per the table of technical parameters The wood must be combusted as dry as possible with at least 15 humidity ma...

Page 7: ...stem A gasket must be inserted between the flanges and bolted together using M8x25 bolts A TS 130 safety discharge valve shall be fitted The fixture must be bolted to one of the lateral 3 4 outlets an...

Page 8: ...st be fitted to the hot water outlet from the boiler as close to the outlet pipe as possible Chart showing connection of the boiler to a forced circulation system indicative chart with no claim to com...

Page 9: ...et connection must conform to the applicable SN standards An unprofessional intervention in the electric wiring of the boiler will result in the latter becoming damaged and may lead to fatal injuries...

Page 10: ...e used to change the resolution of the chart and the buttons are used to move across the time axis The chart memory is roughly for 4 hours 8 3 Adding fuel material Additions of the fuel material take...

Page 11: ...ing process in keeping with the required parameters In all modes basic equithermal controlled fan power is controlled based on the required boiler water output temperature As a default we recommend op...

Page 12: ...difficult to control and the standby time in hot reserve is reduced The problem may be solved by installing a draught controller between the boiler and the chimney The draught controller may be order...

Page 13: ...ush supplied as part of the boiler accessories Use a scraper to clean the entire flue duct including the chimney flap Check the tightness of the chimney flap Where necessary adjust the flap position i...

Page 14: ...the fan by the manual switch and wait for the chimney to cool down entirely about 1 hour If the boiler temperature keeps rising and you can still heat the flap flapping a draught controller needs to b...

Page 15: ...r maintains the boiler output temperature in keeping with the user defined fixed temperature value Equithermal The controller must be equipped with an outdoor temperature sensor The controller will ca...

Page 16: ...oller where the former must be fitted with a potential free switching contact for an equithermal design an outdoor temperature sensor must be connected to be positioned on the northern side of the bui...

Page 17: ...e Ecomax control panel The opening in the bottom right hand side corner of the base serves the conducting of the cabling under the boiler s sheet shell L Power supply MS PE N Secondary circuit circula...

Page 18: ...36 72 25 width height depth Supply voltage 24VDC Maximum input power 5VA Protection to EN60529 IP2X Operating temperature up to 60 C Designed to EN60730 1 2 2001 EMC tested to EN 61000 4 2 EN 61000 4...

Page 19: ...expansion vessels have been adhered to Note When notifying a defect the present Warranty Certificate must be submitted at all times and the exact address and the circumstances in which the defect occ...

Page 20: ...plaint proves unjustified i e the defect or leakage of the weldment is not confirmed by the service engineer the lodger of the complaint will be charged with the costs associated with the inspection a...

Page 21: ...01 Vala sk Mezi Bank details Komer n banka a s account no 1608851 0100 Reg no 47674105 VAT no CZ 47674105 Phone Sales Dept 571 675 589 Secretariat 571 611 250 Production 571 675 405 Sourcing 571 675...

Reviews: