Technical parameters
Boiler type
ECOMAX 25
ECOMAX 35
ECOMAX 42
Nominal power
kW
25
35
42
Chute volume
Dm
3
120
170
200
Water volume
Dm
3
60
68
78
Outlet branch diameter
mm
160
160
160
Maximum boiler width
mm
612
612
712
Maximum boiler depth
mm
850
1000
1120
Maximum boiler height
mm
1200
1200
1475
Chute depth
mm
500
500
650
Maximum log diameter
mm
220
220
220
Maximum log length
mm
300
500
500
Operating chimney draught
Pa
20-25
20-25
20-25
Maximum working overpressure
kPa
200
200
200
Maximum noise level
dB
65
65
65
Efficiency
%
83
81
79
Mass
kg
270
360
454
Operating voltage
V/Hz
230/50
230/50
230/50
Electric power requirement
W
21
21
41
Electric power requirement with electronic
control
W
30
30
50
Protection
IP 20
IP 20
IP 20
Nominal power and efficiency were measured at 11% firewood humidity
5. Fuel material
The fuel material specified is lump wood. No wood quality is specified. It is recommended to burn lump wood cut in maximum
lengths as per the table of technical parameters. The wood must be combusted as dry as possible, with at least 15% humidity
max. Damp wood releases water when combusted, which then condensates on the walls of the boiler body and the chimney. This
results in the emergence of aggressive substances which markedly reduce the boiler and chimney life. Burning damp wood also
results in a marked boiler power reduction.
Indicative table of the calorific value of wood mass depending on the water content
Humidity
Calorific value
( kWh/kg)
(%)
Coniferous
Deciduous
15
4.329
4.057
20
4.035
3.779
25
3.740
3.500
30
3.446
3.222
35
3.151
2.943
40
2.856
2.664
45
2.562
2.386
50
2.267
2.107
55
1.973
1.829
60
1.678
1.550
6. Accessories
The following accessories are supplied along with the boiler:
Steel brush
1 unit
Screw M8 x 25
8 units Filling valve
1 unit
Scraper
1 unit
Nut M8
8 units Gasket
2 units
Discharge fan 1 unit
Washer 8.2
8 units Warranty Certificate
1 item
Counterflanges 2 units
Operating Manual
1 item