Notice:
In the inhibited mode, the firewood does not burn but rather smoulders and imperfect combustion occurs, releasing smoke gases
at an inappropriate composition. The boiler gets clogged and tars in the chute thus reducing its life.
In terms of heating ecology and boiler life, excessive heat energy or scheduling of the heating process should be addressed
by means of storage tanks and their controlled discharging.
Make sure the firewood is as dry as practicable, see Chapter 5.
8.4 Control principle
The controller covers the automated burning process in keeping with the required parameters. In all modes (basic, equithermal,
controlled) fan power is controlled based on the required boiler water output temperature.
As a default, we recommend operating the boiler in automatic mode. As a result, the control of the extraction fan is automated
without the need for an intervention by the user. The only setting that must be done is that of the maximum output boiler water
temperature.
The burning process is divided into three operating modes shown in the image below.