Statistics and Batch Output File Extensions
119
Operator Manual
OPEX Corporation
6.1.5. Reject Terms
The Rejects section lists the reasons for the rejected items and how many
items were rejected for each reason.
Table 6-4: Reasons for rejected items
Length Too
Long
Results when an image is longer than the maximum
allowable image size of the system or when outsorting is set
to reject an image longer than a defined length.
Length Too
Short
Results when outsorting is set to reject an image shorter
than a defined length.
Gap Too Small
Results when the gap between pieces is shorter than the
minimum feed gap defined in the machine parameters.
Too Thin
Results when out sorting is set to reject a piece thinner than
a defined minimum allowable thickness.
Too Thick
Results when out sorting is set to reject a piece thicker than
a defined maximum allowable thickness.
Unable to
Capture Image
Results when the imager fails to capture the image within
the period of time that it is expected to.
Unable to
Process Image
Results when an image fails processing due to a failure
other than running out of processing time.
Blank Image
Detected
Results when a job is set to reject blank pages and the
piece was determined to be a blank page.
Does Not Match
Expected Page
Types
Results when the system could not match a piece to any of
the page types in a particular job.
Bad MICR Read
Results when the result from the combined MICR read does
not have sufficient valid characters or a valid checksum.
Batch Ticket
Expected
Results when a piece is identified as something other than a
batch ticket when the system is expecting a batch ticket.
Stub Expected
Results when a piece is identified as something other than a
stub when the system is expecting a stub.
Check Expected
Results when a piece is identified as something other than a
check when the system is expecting a check.
Summary of Contents for Falcon+
Page 10: ...10 Table of Contents Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Page 16: ...16 Introduction Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Page 26: ...26 Overview Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Page 64: ...64 Operation Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Page 132: ...OPEX Corporation 305 Commerce Drive Moorestown NJ 08057 4234 USA http www opex com...