Sect
ion 4
APPLICATION SETTING EX
AMPLE
S
Section 4
Measuring the Twist of a Workpiece
4-15
ZS-MDC
User’s Manual
Press MENU key - ESC key.
2.
Select [TASK1].
[SENSING]-[CALC]-[CALC]-[STEP]
3.
Set the expression of TASK1.
INPUT X: INPUT A
INPUT Y: INPUT B
4.
Following the same procedure as 2 to 3, set
up TASK2.
INPUT X: INPUT D
INPUT Y: INPUT C
5.
Following the same procedure as 2 to 3, set
up TASK2.
INPUT X: TASK 1
INPUT Y: TASK 2
▲
1
TASK1
3
TASK3
2
TASK2
4
TASK4
▲
1
INPUT X
2
INPUT Y
Input A
Input B
Input C
Input D
Input A
Input B
Input C
Input D
Input A
Input B
Input C
Input D
Summary of Contents for ZS-MDC